The EvoCheck GM-700S is a premium blood glucose monitoring system powered by GDH-FAD (Glucose Dehydrogenase — Flavin Adenine Dinucleotide) enzyme technology — a reagent method that minimises oxygen interference for highly reliable readings across a wide range of patient conditions. Marketed in Pakistan by PharmEvo, the GM-700S is based on the Bionime GM700S platform, compliant with both ISO 15197:2013 and ISO 15197:2015 accuracy standards.
The side-insert strip design is a defining feature of the GM-700S. Rather than inserting from the top or bottom, strips slot in from the side of the meter — keeping blood away from the meter’s main body for improved hygiene. Auto-coding activates automatically upon strip insertion, eliminating manual calibration. With a minimum sample volume of just 0.75 µL and results in 5 seconds, daily testing is fast and comfortable.
The GM-700S features a wide HCT (haematocrit) range of 20–70%, making it suitable not only for standard adult monitoring but also for neonatal patients, elderly users, and those with anaemia. Meal markers allow pre- and post-meal readings to be tagged for better dietary tracking. Memory stores 500 results with date and time stamps.
Why Choose EvoCheck Blood Glucose Monitor
- GDH-FAD Enzyme Technology: Minimises oxygen interference for consistent, reliable results across a wider range of clinical conditions.
- Side-Insert Strip Design: Unique hygienic design that prevents blood from contacting the meter body. Strip is rotated and pulled upward to remove after use.
- Auto-Coding: Automatic calibration upon strip insertion — no manual coding required.
- Small Sample Size: Only 0.75 µL of blood required from capillary, venous, arterial, or neonatal sources.
- Fast 5-Second Results: Blood glucose reading appears 5 seconds after blood is applied.
- Wide Measuring Range: 10 to 600 mg/dL (0.6–33.3 mmol/L).
- Wide HCT Range: 20–70% (for glucose ≤200 mg/dL) — suitable for neonatal, elderly, and anaemic patients.
- Meal Markers: Tag readings as pre-meal or post-meal to track glucose in relation to food intake.
- 500-Result Memory: Stores 500 readings with date and time stamps.
- ISO 15197:2013 and 2015 Compliant: Meets current and previous international accuracy standards.
- Compact Design: 82 × 45 × 15.5mm, 43g.
Product Specifications
| Brand (Pakistan) | EvoCheck (PharmEvo) |
| Model | GM-700S |
| Enzyme / Method | GDH-FAD / Electrochemical sensor |
| Coding | Auto-coding |
| Sample Volume | 0.75 µL (minimum) |
| Blood Sample Types | Capillary, venous, arterial, neonatal |
| Result Time | 5 seconds |
| Measuring Range | 10–600 mg/dL (0.6–33.3 mmol/L) |
| HCT Range | 20–70% (glucose ≤200 mg/dL); 20–60% (glucose >200 mg/dL) |
| Memory | 500 results with date and time |
| Meal Markers | Pre-meal and post-meal |
| Strip Design | Side-insert |
| Display Area | 34 × 27.5mm |
| Dimensions | 82 × 45 × 15.5mm |
| Weight | 43g (±5g) |
| Battery | 1 × CR2032 |
| Operating Temperature | 6–44°C |
| Operating Humidity | 10–90% |
| Quality Standard | ISO 15197:2013 and ISO 15197:2015 |
Usage Instructions
- Insert a GM-700S test strip into the side socket of the meter — the meter powers on and auto-codes.
- Wash and dry hands. Use a lancing device to obtain a 0.75 µL blood sample from fingertip, forearm, palm, or approved alternative site.
- Touch the blood drop to the sample entry port on the strip edge — blood is drawn in automatically.
- Wait 5 seconds for the reading to appear. Select the appropriate meal marker if needed.
- Rotate and pull the strip upward to remove it after use.
- Record your result or review memory. Refer to the included user manual for full guidance.
Storage and Maintenance
- Store the meter between -10°C and 60°C. Store test strips at 4–30°C below 90% humidity in their sealed container.
- Keep away from direct sunlight, heat, and moisture.
- Wipe the meter casing with a soft, dry cloth. Do not submerge in water.
- Replace the CR2032 battery when the low battery indicator appears.
- Keep out of reach of children.
Warnings and Precautions
- For in vitro diagnostic use only — external blood glucose testing only.
- Use only EvoCheck GM-700S compatible test strips.
- Do not use expired test strips or lancets.
- Dispose of used lancets in a puncture-resistant sharps container.
- Always consult a healthcare professional to interpret readings and manage blood glucose.
- Keep out of reach of children.
Package Contents
- 1 × EvoCheck GM-700S Blood Glucose Meter
- 10 × Test Strips
- 1 × Control Solution
- 1 × Lancing Device
- 10 × Lancets
- 1 × CR2032 Battery
- 1 × Carrying Case
- 1 × Log Book
Frequently Asked Questions
What makes the side-insert strip design better?
The side-insert design positions the blood sample entry point away from the meter body. After testing, the strip is rotated and pulled upward to remove — eliminating the need to touch the used strip directly and reducing the risk of blood contaminating the meter.
Why is GDH-FAD enzyme technology important?
GDH-FAD does not react with oxygen the way glucose oxidase does. This means it provides more stable, consistent results in patients with abnormal oxygen levels — such as those on oxygen therapy or at high altitude — and is less prone to interference from other sugars like maltose.
Is the EvoCheck GM-700S suitable for neonatal patients?
Yes. The wide HCT range (20–70% for glucose ≤200 mg/dL) makes the GM-700S suitable for neonatal, elderly, and anaemic patients whose haematocrit values may fall outside the range of standard meters.
How many readings does the memory store?
The GM-700S stores 500 test results with date and time stamps. Meal markers can be applied to readings to help track pre- and post-meal glucose trends.
Is the EvoCheck GM-700S ISO certified?
Yes. The GM-700S is compliant with both ISO 15197:2013 and ISO 15197:2015 — the international accuracy standards for blood glucose monitoring systems.










Reviews
There are no reviews yet.