EvoCheck GM-700S Blood Glucose Monitoring System. GDH-FAD enzyme, side-insert strip design, auto-coding, 0.75µL sample, 5-second results, 10–600 mg/dL range, wide HCT 20–70%, 500-result memory, meal markers, ISO 15197:2013 & 2015 compliant.

Sold Out

This product is currently unavailable

Notify when available
Model

GM-700S

Estimated delivery:July 15, 2026 - July 17, 2026
Secure Payment options. Pay Safely with Visa Credit Card. Pay Safely with Visa Credit Card. Pay Safely with Master Credit Card. Pay Safely with Master Credit Card. Pay safely with Union Pay Pay safely with Union Pay Pay Safely in our Bank Account. Pay Safely in our Bank Account. Pay safely with JazzCash. Pay safely with JazzCash. Pay safely with Easy Paisa. Pay safely with Easy Paisa. Pay safely with uPaisa Pay safely with uPaisa Pay safely at your door. Pay safely at your door.

The EvoCheck GM-700S is a premium blood glucose monitoring system powered by GDH-FAD (Glucose Dehydrogenase — Flavin Adenine Dinucleotide) enzyme technology — a reagent method that minimises oxygen interference for highly reliable readings across a wide range of patient conditions. Marketed in Pakistan by PharmEvo, the GM-700S is based on the Bionime GM700S platform, compliant with both ISO 15197:2013 and ISO 15197:2015 accuracy standards.

The side-insert strip design is a defining feature of the GM-700S. Rather than inserting from the top or bottom, strips slot in from the side of the meter — keeping blood away from the meter’s main body for improved hygiene. Auto-coding activates automatically upon strip insertion, eliminating manual calibration. With a minimum sample volume of just 0.75 µL and results in 5 seconds, daily testing is fast and comfortable.

The GM-700S features a wide HCT (haematocrit) range of 20–70%, making it suitable not only for standard adult monitoring but also for neonatal patients, elderly users, and those with anaemia. Meal markers allow pre- and post-meal readings to be tagged for better dietary tracking. Memory stores 500 results with date and time stamps.

Why Choose EvoCheck Blood Glucose Monitor

  • GDH-FAD Enzyme Technology: Minimises oxygen interference for consistent, reliable results across a wider range of clinical conditions.
  • Side-Insert Strip Design: Unique hygienic design that prevents blood from contacting the meter body. Strip is rotated and pulled upward to remove after use.
  • Auto-Coding: Automatic calibration upon strip insertion — no manual coding required.
  • Small Sample Size: Only 0.75 µL of blood required from capillary, venous, arterial, or neonatal sources.
  • Fast 5-Second Results: Blood glucose reading appears 5 seconds after blood is applied.
  • Wide Measuring Range: 10 to 600 mg/dL (0.6–33.3 mmol/L).
  • Wide HCT Range: 20–70% (for glucose ≤200 mg/dL) — suitable for neonatal, elderly, and anaemic patients.
  • Meal Markers: Tag readings as pre-meal or post-meal to track glucose in relation to food intake.
  • 500-Result Memory: Stores 500 readings with date and time stamps.
  • ISO 15197:2013 and 2015 Compliant: Meets current and previous international accuracy standards.
  • Compact Design: 82 × 45 × 15.5mm, 43g.

Product Specifications

Brand (Pakistan) EvoCheck (PharmEvo)
Model GM-700S
Enzyme / Method GDH-FAD / Electrochemical sensor
Coding Auto-coding
Sample Volume 0.75 µL (minimum)
Blood Sample Types Capillary, venous, arterial, neonatal
Result Time 5 seconds
Measuring Range 10–600 mg/dL (0.6–33.3 mmol/L)
HCT Range 20–70% (glucose ≤200 mg/dL); 20–60% (glucose >200 mg/dL)
Memory 500 results with date and time
Meal Markers Pre-meal and post-meal
Strip Design Side-insert
Display Area 34 × 27.5mm
Dimensions 82 × 45 × 15.5mm
Weight 43g (±5g)
Battery 1 × CR2032
Operating Temperature 6–44°C
Operating Humidity 10–90%
Quality Standard ISO 15197:2013 and ISO 15197:2015

Usage Instructions

  1. Insert a GM-700S test strip into the side socket of the meter — the meter powers on and auto-codes.
  2. Wash and dry hands. Use a lancing device to obtain a 0.75 µL blood sample from fingertip, forearm, palm, or approved alternative site.
  3. Touch the blood drop to the sample entry port on the strip edge — blood is drawn in automatically.
  4. Wait 5 seconds for the reading to appear. Select the appropriate meal marker if needed.
  5. Rotate and pull the strip upward to remove it after use.
  6. Record your result or review memory. Refer to the included user manual for full guidance.

Storage and Maintenance

  • Store the meter between -10°C and 60°C. Store test strips at 4–30°C below 90% humidity in their sealed container.
  • Keep away from direct sunlight, heat, and moisture.
  • Wipe the meter casing with a soft, dry cloth. Do not submerge in water.
  • Replace the CR2032 battery when the low battery indicator appears.
  • Keep out of reach of children.

Warnings and Precautions

  • For in vitro diagnostic use only — external blood glucose testing only.
  • Use only EvoCheck GM-700S compatible test strips.
  • Do not use expired test strips or lancets.
  • Dispose of used lancets in a puncture-resistant sharps container.
  • Always consult a healthcare professional to interpret readings and manage blood glucose.
  • Keep out of reach of children.

Package Contents

  • 1 × EvoCheck GM-700S Blood Glucose Meter
  • 10 × Test Strips
  • 1 × Control Solution
  • 1 × Lancing Device
  • 10 × Lancets
  • 1 × CR2032 Battery
  • 1 × Carrying Case
  • 1 × Log Book

Frequently Asked Questions

What makes the side-insert strip design better?

The side-insert design positions the blood sample entry point away from the meter body. After testing, the strip is rotated and pulled upward to remove — eliminating the need to touch the used strip directly and reducing the risk of blood contaminating the meter.

Why is GDH-FAD enzyme technology important?

GDH-FAD does not react with oxygen the way glucose oxidase does. This means it provides more stable, consistent results in patients with abnormal oxygen levels — such as those on oxygen therapy or at high altitude — and is less prone to interference from other sugars like maltose.

Is the EvoCheck GM-700S suitable for neonatal patients?

Yes. The wide HCT range (20–70% for glucose ≤200 mg/dL) makes the GM-700S suitable for neonatal, elderly, and anaemic patients whose haematocrit values may fall outside the range of standard meters.

How many readings does the memory store?

The GM-700S stores 500 test results with date and time stamps. Meal markers can be applied to readings to help track pre- and post-meal glucose trends.

Is the EvoCheck GM-700S ISO certified?

Yes. The GM-700S is compliant with both ISO 15197:2013 and ISO 15197:2015 — the international accuracy standards for blood glucose monitoring systems.

Reviews

There are no reviews yet.

Only logged in customers who have purchased this product may leave a review.

EvoCheck GM-700S Blood Glucose Monitoring System-1 EvoCheck GM-700S Blood Glucose...

Original price was: Rs. 3,400.Current price is: Rs. 2,000.