The On Call® EZ II Glucometer is a compact, affordable, and reliable blood glucose monitoring system manufactured by ACON Laboratories. Designed for both home self-monitoring and professional clinical use, it offers fast and accurate results using glucose oxidase amperometric technology — requiring only 1 µL of blood and delivering plasma-equivalent readings in approximately 10 seconds.
The meter uses a Code 690 chip for automatic calibration with each batch of strips. A simple two-step testing process makes it accessible for users of all ages, and the included carrying case keeps all components organised for use at home or on the go.
The complete starter pack includes the meter, test strips, lancets, lancing device, code chip, and all accessories needed to begin testing immediately out of the box.
Why Choose On Call Blood Glucose Monitor
- Small Sample Size: Requires only 1 µL of blood — minimising discomfort during finger-prick testing.
- Fast Results: Plasma-equivalent blood glucose reading in approximately 10 seconds.
- Wide Measuring Range: 20 to 600 mg/dL — suitable for monitoring both low and high glucose readings.
- Automatic Code Chip Calibration: Code 690 chip calibrates the meter automatically with each new box of strips.
- Simple Two-Step Process: Insert strip, apply blood — result in seconds.
- Portable and Compact: Lightweight design with an included carrying case for home and travel use.
- Complete Starter Pack: Everything needed to begin testing is included — no separate purchases required.
- ACON Laboratories Quality: Manufactured by ACON Laboratories, a globally recognised in vitro diagnostics company.
Product Specifications
| Brand / Manufacturer | ACON Laboratories |
| Model | On Call EZ II |
| Measurement Method | Electrochemical (amperometric) |
| Sample Size | 1 µL |
| Result Time | Approximately 10 seconds |
| Measuring Range | 20 to 600 mg/dL |
| Calibration | Code 690 chip (plasma-equivalent) |
| Testing Process | Two-step |
| Storage | Room temperature, away from heat, sunlight, and moisture |
Usage Instructions
- Insert the Code 690 chip into the meter if using a new box of strips.
- Insert one test strip into the meter — it powers on automatically.
- Wash and dry your hands. Use the lancing device to obtain a small blood sample (1 µL) from your fingertip.
- Touch the tip of the test strip to the blood drop — the strip draws in the sample automatically.
- Wait approximately 10 seconds for the blood glucose reading to appear on the display.
- Record your result. Dispose of the used strip and lancet safely.
- Refer to the included user manual for complete guidance on meter use and result interpretation.
Storage and Maintenance
- Store the meter and strips at room temperature, away from heat, direct sunlight, and moisture.
- Do not submerge the meter in water — wipe clean with a soft, lightly damp cloth if needed.
- Replace the battery when the low battery indicator appears.
- Keep out of reach of children.
Warnings and Precautions
- For in vitro diagnostic use only — external blood glucose testing only.
- Use only On Call EZ II test strips (Code 690) with this meter. Other strips will give inaccurate results.
- Always insert the correct Code 690 chip when starting a new box of test strips.
- Do not use expired test strips or lancets.
- Dispose of used lancets in a puncture-resistant sharps container.
- Consult a healthcare professional before making treatment decisions based on blood glucose readings.
- Keep out of reach of children.
Package Contents
- 1 × On Call EZ II Blood Glucose Meter
- 10 × On Call EZ II Test Strips (Code 690)
- 1 × Code Chip
- 10 × Sterile Lancets
- 1 × Lancing Device
- 1 × Carrying Case
- 1 × User Manual
- 1 × Quick Reference Guide
- 1 × Warranty Card
Frequently Asked Questions
Who manufactures the On Call EZ II?
The On Call EZ II is manufactured by ACON Laboratories — a globally recognised in vitro diagnostics company known for a wide range of blood glucose monitoring systems available across multiple countries.
Which test strips are compatible with the On Call EZ II?
The On Call EZ II uses On Call EZ II Test Strips (Code 690). These strips are not interchangeable with On Call Extra or On Call PLUS strips. Always use the correct strip model to ensure accurate results.
What is the Code 690 chip for?
The Code 690 chip calibrates the meter to match the specific batch chemistry of the accompanying test strips. Insert the chip when you open a new box of strips — this ensures accurate, batch-specific calibration without manual code entry.
What is the measuring range of this glucometer?
The On Call EZ II measures blood glucose from 20 to 600 mg/dL — covering the full clinically relevant range from hypoglycaemic to severely hyperglycaemic readings.
What is included in the starter pack?
The starter pack includes the meter, 10 test strips, 1 code chip, 10 sterile lancets, 1 lancing device, 1 carrying case, user manual, quick reference guide, and warranty card — everything needed to begin testing immediately.
How do I dispose of used lancets?
Used lancets should be disposed of in a puncture-resistant sharps container. Do not place in regular household waste — they can cause injury. Contact your local pharmacy or healthcare provider about sharps disposal services.